Spittin' gas out of the filler. floors out - any suggestions?

boaterntx

Seaman Apprentice
Joined
Oct 13, 2004
Messages
30
My 1990 18' Glastron runabout has always had a problem of spittin gas back out the fill hole while pumping gas unless I pump really slowly & pause often to allow the gas to vent. I had always assumed that this was because the vent was below the gas line while gassing up. I'm in the process of reflooring the boat & have the gas take completely exposed (pics later). I was wondering if any of you guys had any suggestion as to how to fix this problem (especially now that can remove the tank)

Thanks

added info: it's a 17gal plastic tank mounted under the floor in the middle of the boat. the fill tube & fuel pickup lines enter the tank stern side & the vent enters tank bow side. the tank has somewhat of a U shape with the fill tube & vent being a couple inchs higher than the main resevior. I should post pics at some point today.
 

studlymandingo

Commander
Joined
Mar 22, 2006
Messages
2,716
Vent Issues

Vent Issues

Sounds like your tank vent may be stopped up or inadequate. If it is not plugged, you could tee the line close to the tank and install an additional vent.​
 

Coors

Captain
Joined
Dec 8, 2006
Messages
3,367
Re: Spittin' gas out of the filler. floors out - any suggestions?

Any problems running? Anti-syphon vavle could use looking at.
 

Bondo

Moderator
Staff member
Joined
Apr 17, 2002
Messages
71,082
Re: Spittin' gas out of the filler. floors out - any suggestions?

the fill tube & fuel pickup lines enter the tank stern side & the vent enters tank bow side.

Ayuh,....... That's about as Good as it Gets,........
Having the Fill forward with the Vent would be Nice, but Not necessary......
Vent forward is usually the Key.......

Does your Vent line have a Loop in it,..??..??......

It Should,....... It'll keep Water out of your Fuel......
And it HAS to be looped Up, to drain,+ Not down,....It'll back up if Down....
 

Gary H NC

Fleet Admiral
Joined
Dec 1, 2005
Messages
8,972
Re: Spittin' gas out of the filler. floors out - any suggestions?

My Starcraft with a 3/8 size vent line is the same way. Just have to fill it slow.Just the way some tanks are made..:rolleyes:
 

Bondo

Moderator
Staff member
Joined
Apr 17, 2002
Messages
71,082
Re: Spittin' gas out of the filler. floors out - any suggestions?

3/8" is a Fuel Line Size,............. Vents are Usually 5/8"............
 

boaterntx

Seaman Apprentice
Joined
Oct 13, 2004
Messages
30
Re: Spittin' gas out of the filler. floors out - any suggestions?

Any problems running? Anti-syphon vavle could use looking at.

Runs fine.

Does your Vent line have a Loop in it,..??..??......

It Should,....... It'll keep Water out of your Fuel......
And it HAS to be looped Up, to drain,+ Not down,....It'll back up if Down....

I don't recall a loop, I'll check this evening.
 

boaterntx

Seaman Apprentice
Joined
Oct 13, 2004
Messages
30
Re: Spittin' gas out of the filler. floors out - any suggestions?

okay, no Loop & the vent line is 5/8's . I guess it's just something I will have to live with.
 

studlymandingo

Commander
Joined
Mar 22, 2006
Messages
2,716
Re: Spittin' gas out of the filler. floors out - any suggestions?

Is the vent working properly? I have had them stopped up with salt before.​
 