  1. M

    Automatic Bilge not running

    I put a 5 amp fuse in there. I believe that’s the correct size for the Rule automatic 500 pump.
  2. M

    Automatic Bilge not running

    If the pump works at the switch where the brown/white wire is, then I can assume that the fault has to be either in the brown wire or the fuse, I think. As I mentioned, I couldn’t get the test button to work but the pump does turn on when using the switch. Thanks for your quick responses!
  3. M

    Automatic Bilge not running

    I can’t recall the exact model without going out there and sticking my head in the hull. But it is one of those that has the test button. I couldnt get the test button to work but thought maybe I was doing something wrong. I’ll try a water test to confirm. Also, do you think it makes a...
  4. M

    Automatic Bilge not running

    I have a Rule auto sensing bilge that has three wires , black (ground), brown (positive automatic) and brown/white (positive manual). I seem to be having some wiring issues and need guidance please as I’m new to this. I’ve connected to black ground and brown positive (with in line fuse)...