FORUM RULES UPDATED - The forum rules have been updated to continue to provide a friendly and safe environment for our member community. Please take a moment to review the updated rules and our terms of use and privacy policy. Click here for Forum Rules which has links to the 'terms of use' and 'privacy policy'.
In Other News . . .
You will notice a few enchancements to the forums to make your experience better. These include: Email Notifications, Thread Previews, Thread Starter Notation, and Emoji Options on the 'Like' icon. . .
Additionally, the merchant portions of the website have been updated and are now operational. . . . Check out iBoats for all your boating gear.
Just checked stator DVA. "Open circuit voltage at cranking should be no less than 100 volts DVA" per the service manual. My reading was 50 volts.
Also reminder that target resistance between G/W and W/G is 380-430 ohms. Measured resistance 180-250 ohms.
Perhaps there's a slight voltage leak to...
Engine cranks but no spark. All 6 CDMs check out fine. Stop circuit checks out fine. Having difficulty determining if it's the stator, trigger or control module. Appreciate any help with this. Here's the info:
TRIGGER
Target resistance 1100-1400 ohms. Measured resistance 2000+ ohms.
DVA target...
Engine cranks but no spark. All 6 CDMs check out fine. Stop circuit checks out fine. Having difficulty determining if it's the stator, trigger or control module. Appreciate any help with this. Here's the info:
TRIGGER
Target resistance 1100-1400 ohms. Measured resistance 2000+ ohms.
DVA target...