  1. R

    Tohatsu on fire!!

    Some will argue.-----Water in a test bucket must be 6" above the impeller.----Many will agree on that simple fact !!!
  2. R

    95 johnson 130hp 2 stroke...help please

    I my opinion those compression numbers will not keep it from actually " running "-----Those compression numbers and slight scoring indicate to me that it will not run / idle well.----But some folks can only say ---" It runs so there is not much wrong "-----Sorry just my opinion here.
  3. R

    1983 Johnson 115 hp not coming up to full power

    Take head off and have a look.------Some folks can not / will not accept that these are fine motors and worth rebuilding.-----Many shops no longer work on these simple motors.-----And having a shop as your servant can be expensive.----Your decision.----A new 115 HP technical marvel might set you...
  4. R

    2000 model year Johnson J175XVSSS gearcase removal

    Well----That might help you see and understand this simple procedure.----Might help on re-assembly.-----Do not turn the shift rod during this repair procedure.
  5. R

    2000 model year Johnson J175XVSSS gearcase removal

    Stand on the starboard side of the motor.----Find the L-shaped shift lever below the bottom carburetor.-----Remove hitch pin on that shaft.-----Now push that shaft to the port side of the motor.----Rotate that shaft and shift rod is now disconnected.
  6. R

    Tohatsu on fire!!

    Water in a test bucket must be 6" above the impeller.----Posting another picture showing water level will help.-----Just trying to help you .----But now I suggest an appointment at your nearest boat shop !!
  7. R

    1992 E10RELENA won't go over 3k

    The yellow wires are for the battery charging !!----Sounds like the motor is running on one cylinder.-----Motor needs 4 things to run.-----Fuel.----Compression.----Spark at the right time.------Crankcase compression.------Crankcase compression is not easy to diagnose for a novice.------Check for...
  8. R

    95 johnson 130hp 2 stroke...help please

    It should start with the electric primer activated during cranking.----It works by spraying fuel in there just the same as you spraying carb cleaner in there.----So test operation of the primer valve.------Load test your battery and take starter apart for inspection.
  9. R

    Tohatsu on fire!!

    I think you need more water in your test bucket.-----And run it at night to look for a spark.
  10. R

    95 johnson 130hp 2 stroke...help please

    Might have a seal ring failing on crankshaft.-----Difficult for a novice to diagnose.-----Are you pushing the key in and holding it in while cranking for cold start ??
  11. R

    Tohatsu on fire!!

    Find the bare wire that is causing a spark.-----Repair the fuel leakage.
  12. R

    1983 Johnson 115 hp not coming up to full power

    You must know that these V-4 crossflow engines are famous for broken rings.---Post the compression numbers.---Easy and no beer tokens needed to do that.----And make sure there is strong spark ( 3/8" gap ) on the 4 leads.
  13. R

    A Unique problem I have never seen

    Curious to find out how " clean oil " got in the heat exchanger.
  14. R

    Poor acceleration

    If primer valve stays open motor will flood with fuel.-----Pinch off fuel supply to primer as a test.----Replace the ignition key.
  15. R

    A Unique problem I have never seen

    Is it a closed cooling system that should have antifreeze in it ??
  16. R

    93 Mercury classic 40HP ran perfect and now dies intermittently

    Compression test is first thing to do.
  17. R

    Honda BF115 seized from sitting

    Step #1 is to remove lower unit.---Then see if powerhead will rotate.----It need to be removed sooner or later to check impeller anyway.
  18. R

    1972 Merc 650E 3 CYL....fuel system Qs

    Many of those Haulover inlet / Miami river boats are charters.----Customers have no issue to pay for the one time " experience this " trips.
  19. R

    82 Evinrude 115hp: How to run on stand?

    Motor will have to be stopped by running out of fuel or turning primer valve to manual mode.