Recent content by Fed

  1. F

    85 hp evinrude takes a few moments to quit after shutting down.

    Go back to the threads and report your findings to close. After you pump the fuel primer the carbs will be full so at that stage you don't need a fuel pump for starting. Different to the later models that use a fuel primer valve your's uses the good old fashioned choke butterflys.
  2. F

    85 hp evinrude takes a few moments to quit after shutting down.

    Closing off your outstanding threads would lead to better answers in this one. I seriously doubt a bad fuel pump was the cause of your hard starting. Not shutting down could be caused by one or both powerpacks not grounding properly, also check connections between powerpacks & keyswitch and...
  3. F

    suzuki wiring diagram 2001 dt140

    See if this turns out.
  4. F

    Gear oil change ?

    Shop evinrude shows them both with the same part number 0333572 described as 0 rings.
  5. F

    Blower motor popping circuit breaker

    Resistance within a circuit reduces current. Check for short circuits in wiring and blower motor.
  6. F

    Replacing steering in a 97 Stratos

    Probably be worth the time to find out why it's tight before spending any money on it.
  7. F

    1990Yamaha 175 Steering Issue?

    I have had success with Mercs by binding around the bottom with cloth tape then securing with a worm drive hose clamp to stop the grease coming out the bottom & forcing it out the top instead. If my memory serves me I think I may have also warmed it up just a little.
  8. F

    Empty trailor weight

    You can calculate the boat weight by measuring the weight on the hitch then moving the boat a set amount on the trailer then remeasuring the weight on the hitch. After that all you have to do is subtract the boat weight from the weight of the whole rig. My first choice would be to chuck the boat...
  9. F

    Mounting battery selector switch ideas

    Jumper leads are handy on boats.
  10. F

    trim relay mystery-2000- 150 h.p. Johnson

    Something's not adding up that's for sure. Can we safely assume this is the correct circuit diagram? https://maxrules.com/graphics/omc/wiring/TnTwiring.gif
  11. F

    trim relay mystery-2000- 150 h.p. Johnson

    Is this a fault that just happened or is the motor new to you and it's been like this since you got it?
  12. F

    trim relay mystery-2000- 150 h.p. Johnson

    I can't explain what's happening but here's where I'd go to move forward. Confirm the exact model of the motor then get either a genuine factory manual or a genuine circuit diagram for that model. Interesting point, the relays in post #13 appear to be different from each other.
  13. F

    trim relay mystery-2000- 150 h.p. Johnson

    Could be wrong but I think the relays are electrically interlocked so you may be replacing the wrong relay. By that I mean power going to the UP relay also has to go through a set of normally closed contacts on the DOWN relay which may not be closed when the relay is not energised. Instead of...
  14. F

    '89 Johnson 60HP overheating

    Sometimes it doesn't occur at all with the motor running flawlessly for over an hour. I suspect you're being led down the garden path regarding corrosion being the problem. I'd be revisiting the temp sensor (2 wires or 1?) and the whole alarm setup including power pack before stripping it down...