    1995 Johnson SPL extra telltale question

    post a close up pic where water exists the gc ... is it out some hole in the GC ?, watre pressure pick-up for the speedo ?? etc.. water drain hole ??
  2. C

    2005 PLSOR cuts after starting

    if so why not add a direct B+ supply to the suspect part as a test or monitor it with a test lamp or vom to see whatahappens when you release the starter cct.
  3. C

    2005 PLSOR cuts after starting

    Chat had several options... here is one... fwiw.... 5. Primer/choke masking lean condition During cranking, the primer enriches fuel mixture. If carbs are badly clogged, engine may only run on primer fuel while cranking. More likely if: engine only fires with choke/primer sneezes or coughs...
  4. C

    2005 PLSOR cuts after starting

    if starter checks out ok see chat GPT for possible options to investigate just ask why it stops after cranking.
  5. C

    Cowling gasket on early 70s omcs

    https://www.amazon.ca/s?k=car+door+trim&crid=2DENDBBI3EPFF&sprefix=car+door+trim+%2Caps%2C343&ref=nb_sb_noss_2
  6. C

    Cowling gasket on early 70s omcs

    I have used automotive car door trim on some smaller engines....check sizes first see amazon if you can't find anything oem
  7. C

    1994 Evinrude 140 water pump question

    sometimes asking chat gpt will provide valueable info if not 100% accurate all the time... the child is learning we are not up to HAL 9000 yet. even he was flaky in the end
  8. C

    1975 25 hp evinrude 25502B

    great news thanks for the feedback ... one down.. thousands to go :)
  9. C

    1972 johnson 25 hp ignition points

    the only place to measure is on the screw side....and the engine body with the VOM scale at the lowest setting... personnaly I realy like analog meters with a needle adjustment to set the 0 value on the scale when probes are shorted. the rotating cam will open the point gap at he high...
  10. C

    1975 25 hp evinrude 25502B

    well that is good. HV side anyway being new coils and all Make certain the coil's "pulse wire" from the magneto has continuity see diagram most likely like your wiring. https://maxrules.com/graphics/omc/wiring/1973-76_18-25.jpg if similar make certain that the "suspect coil" ... kill...
  11. C

    1975 25 hp evinrude 25502B

    what ohms value do you see testing from plug boots to engine frame... post reseults!!
  12. C

    1972 johnson 25 hp ignition points

    did you remove all wires from the point screw because your primary coil wire goes to ground and a bad condenser could be shorted to ground . test only from the screw side and frame ground .......if the points visually open at the high point of the cam you will see infinity (ol) millions of...
  13. C

    Johnson 5.5 CD-20C carb and running issues

    if you plan to service oldies download the free bible on J&E of those years ... ALL the info you need is in there stoore/print locally https://www.socalaomci.com/library/johnson_service_manual_10th_edition.pdf
  14. C

    1972 johnson 25 hp ignition points

    the actual gap isn't all that critical. the timing of the openning is critical see video. .020 is a ballpark using the high point of the cam just adjust the gap openning " time" per video
  15. C

    1994 Evinrude 140 water pump question

    download this one free it likely has all you need and more. https://drive.google.com/drive/folders/1-pyBmXzRaZ16y9sJ1QkSfjnBGwA-HzsB
  16. C

    1994 Evinrude 140 water pump question

    just disconnect the cross pin holding the shift rod near the PH (on the side) models vary .. do not turn (unscrew or screw the shift rod.. keep it aligned when replacing
  17. C

    1962 evinrude fastwin 15036 fuel issue

    the bulb does not stay firm so that is not the problem it is only used to fill the carb then the fuel pump sucks up what it needs. hard to belive 6g/hr burn rate fine for a 50hp carbed Merc WOT pulling skiers but not a 10hp in a barrel !! oily barrel water is fine not an issue 2...