  1. C

    1967 6 hp CD-24 lync & sync instructions

    maybe just the view angle.. but I don't see the oiler wick on the magneto plate... it should b attached with the oiler clip under the coil
  2. C

    9.5 johnson motor tag gone

    Should pump out water !! change the impeller ot inspect what is wrong water normally bypasses the thermostat anyway .. open or not
  3. C

    1967 6 hp CD-24 lync & sync instructions

    the diagram is for a smaller motor like the JW's for your 6hp just put your throttle handle to the START position then line up the cam roller and cam markings has describded for the JW
  4. C

    1999 50hp Johnson 2 stroke won’t start

    why would a presumed «"crack" in a tank cause air to be sucked in the carbs ? Fuel tanks need air to break the negative pressure build, up hence the need for "vents" to replenish the "air space" of missing fuel pulled up by the pump. pumping the fuel bulb hard to fill the carbs...
  5. C

    Ground Wire on EzLoader Trailer--Mystery

    did you measure the white wire ohms resistance with the frame... if it is connected properly (0 ohms) don'T worry where it goes....
  6. C

    Are surge brakes always a PIA?

    16 years no issues with surge brakes on my 18 foot rig
  7. C

    Just a question 1971 18 hp Fastwin

    seen copper on roofs..... last 75-100 years ..going on 70 in my oldies :-)
  8. C

    Johnson BJ50 BELEDS (1996 50 hp 2-cyl) No start.

    qwick test ... have a buddy hold the key on START while you wiggle twist prod the cabling if you gat a reaction on the selenoid/starter you may have a bad connection , bad wire etc... and if you have a volt meter check the selenoid control post for 12v wiggle the neutral switch...
  9. C

    Johnson CD-12

    Doorknocker... can u clarify ? cyl head gasket is the plate gasket behind the spark plug cover powerhead gasket is the base gasket under the PH
  10. C

    Johnson CD-12

    sorry misread.. are we talking cyl head leaks or powerhead leaks
  11. C

    1999 50hp Johnson 2 stroke won’t start

    probably major surgery but..... just get it working and run a good decarb product and retest the compression to see what happens. Then decide on the next step.
  12. C

    1954 Evinrude 7516 Parts

    any pictures...? where is that located on the motor ??
  13. C

    Evinrude angler 5hp hard to steer

    loosen it up big time and see if you can wash out what is likely old dried grease with kerosene or wd-40 . if you y have a zerk (?) push out the old grease with the new set the screw to your liking after
  14. C

    1954 Evinrude 7516 Parts

    what is the issue to resolve
  15. C

    1954 Evinrude 7516 Parts

    what is the problem with you motor
  16. C

    1954 Evinrude 7516 Parts

    that site died off with the demise of adobe...to bad ...:-(
  17. C

    1980 j25rcsa solenoid issue

    Patience (and some crow meat) brings joy :-)
  18. C

    1999 50hp Johnson 2 stroke won’t start

    well great news ... now you need fuel in the cyl and fire on the plugs easiest to check is plugs firing
  19. C

    1980 j25rcsa solenoid issue

    ?? is that meter on 1000v scale...? use 20 put one probe on grd and one on the red starter post turn key to START do you see 10-12v on the starter bat . post yes .. no ? if yes... starter should turn if contact surfaces are clean and battery is good if yes... and starter...